Even though a return air filter is not supplied with this fur-
nace, the return air must be filtered. The installer must sup-
ply filters at the time of installation. Become familiar with
filter location and procedures for removing, cleaning and
replacing them. If needing help, contact the installer of the
furnace or another qualified servicer.
If filter replacement becomes necessary, it must be replaced
with a filter of the same type and size that complies with
UL900 or CAN/ULC-S111 standards.
See the Specification Sheet for filter sizes.
WARNING
PERSONAL INJURY HAZARD
To avoid death or personal injury due to elec-
trical shock, disconnect the electrical power
before removing filters or performing any
maintenance.
Filters must be inspected, cleaned or changed every two
months or as required. It is the owner's responsibility to keep
air filters clean. NOTE: Dirty filters are the most common
cause of inadequate heating or cooling performance.
Upflow Filters (Not Included With Furnace)
To remove the external upflow filter from the external filter
rack, disconnect electrical power to the furnace and follow
the directions provided with the external filter rack kit.
NOTE: If using Media Air Cleaner MAC1 or Electronic Air
Cleaner EAC5, follow the directions that came with the air
cleaner for proper filter removal, cleaning, and replacement
procedures.
Remove the two front panels (louvered panel first). Using a
vacuum cleaner, clean out the blower area, external filter
rack area, and the adjacent area of the return air duct.
Some installations will have throwaway filters. If dirty, these
filters must be thrown away and replaced with two new simi-
lar size throwaway filters. Other installations will have per-
manent filters. If dirty but not torn, these filters must be
cleaned as follows:
Wash, rinse, and dry a permanent filter. Both sides of a metal
filter should be sprayed with a dust adhesive as recom-
mended on the adhesive container. Spray adhesives for use
with permanent metal filters can be found at some hardware
stores.
If badly torn or uncleanable, these filters must be replaced
with permanent filters of the same type and size.
To reinstall filter follow instructions included with extenal fil-
ter rack kit. BE SURE AIRFLOW DIRECTION ARROW
POINTS TOWARDS THE BLOWER.
When the filter is located in the bottom of the furnace on a
bottom return system the filter is held in place by a wire filter
retainer (Figure 6). To change and clean the filter, push back
and up on the wire filter retainer to release it from under the
front lip of the basepan. Slide the filter out and follow clean-
ing or replacement instructions above. Replace filter oppo-
site of removal.
Figure 6
Wire Filter Retainer
Counterflow Filters (Not Included With Furnace)
The furnace-mounted filter rack includes a rack mounted on
the top of the furnace. Two filters fit into the rack and rest
against the sides of the return air plenum, forming a “V” above
the furnace (Figure 7).
Figure 7
Counterflow Furnace Mounted Filter Rack
Remember dirty filters are the most common cause of inad-
equate heating or cooling performance.
NOTE: If using Media Air Cleaner MAC1 or Electronic Air
Cleaner EAC5, follow the directions that came with the air
cleaner for proper filter removal, cleaning, and replacement
procedures.
The filters should be inspected and cleaned or changed ev-
ery two months or as required. In some installations, the